| Home | Contact | SiteMap | English |
    ȸ»ç¼Ò°³   Á¦Á¶»ý»êǰ   ¼öÃâÆÇ¸Åǰ   ¼öÀÔÆÇ¸Åǰ   °í°´Áö¿ø     ä¿ëÁ¤º¸   »ç³»Åë½Å  
   Ȩ /  ¼öÀÔÆÇ¸Åǰ / 
    ¸¶±×³×ƽ ÄÜŹÅÍ

 
SINGLE POLE ON/OFF CONTACTORS (normally open) (SPST)

 
150A AT 50%DUTY, 100A CONTINUOUS DUTY
SW80
SW80A
with microswitch auxiliary contacts

225A AT 50%DUTY, 150A CONTINUOUS DUTY
SW180
SW180A
with microswitch auxiliary contacts

360A AT 50%DUTY, 250A CONTINUOUS DUTY
SW200
SW200A
with microswitch auxiliary contacts

Available with or without magnetic blowouts
 
SINGLE POLE CHANGEOVER CONTACTORS (SPDT)

 
150A AT 50%DUTY, 100A CONTINUOUS DUTY
SW84
SW84A
with microswitch auxiliary contacts

225A AT 50%DUTY, 150A CONTINUOUS DUTY
SW181
SW181A
with microswitch auxiliary contacts

360A AT 50%DUTY, 250A CONTINUOUS DUTY
SW201
SW201A
with microswitch auxiliary contacts

Available with or without magnetic blowouts
 
PAIRED SINGLE POLE CHANGEOVER CONTACTORS
FOR MOTOR REVERSING COMPLETE WIHT LINKS (2 x SPDT)


 
150A AT 50%DUTY, 100A CONTINUOUS DUTY
DC88
DC88A
with microswitch auxiliary contacts

225A AT 50%DUTY, 150A CONTINUOUS DUTY
DC182
DC182A
with microswitch auxiliary contacts

360A AT 50%DUTY, 250A CONTINUOUS DUTY
SW202
SW202A
with microswitch auxiliary contacts

Available with or without magnetic blowouts
 
DOUBLE POLE ON/OFF CONTACTORS (DPST)

 
150A AT 50%DUTY, 100A CONTINUOUS DUTY
SW82
225A AT 50%DUTY, 150A CONTINUOUS DUTY
SW190
SW190A
with microswitch auxiliary contacts

PAIRED DOUBLE POLE ON/OFF
CONTACTORS FOR MOTOR REVERSING
 
150A AT 50%DUTY, 100A CONTINUOUS DUTY
SW822
225A AT 50%DUTY, 150A CONTINUOUS DUTY
SW192
SW192A
with microswitch auxiliary contacts

 
PAIRED SINGLE POLE CHANGEOVER CONTACTORS
FOR MOTOR REVERSING COMPLETE WIHT LINKS (2 x SPDT)

 
150A AT 50%DUTY, 100A CONTINUOUS DUTY
SW121
SW121A
with microswitch auxiliary contacts

 
NORMALLY CLOSED ON/OFF CONTACTORS (SPST & DPST)

 
150A AT 50%DUTY, 100A CONTINUOUS DUTY
SW85
Single pole
SW85A Single pole with microswitch auxiliary contacts

180A AT 50%DUTY, 125A CONTINUOUS DUTY
SW132
Double pole
SW132A Double pole with microswitch auxiliary contacts

225A AT 50%DUTY, 150A CONTINUOUS DUTY
SW185
Single pole
SW185A Single pole with microswitch auxiliary contacts

360A AT 50%DUTY, 250A CONTINUOUS DUTY
SW210
Single pole
SW210A Single pole with microswitch auxiliary contacts

 
TIME DELAY UNITS
 
Maximum 2A at voltages up to 120
TU150 Adjustable from 0 to 5 secs
For delaying the switching on of a contactor coil

 
EMERGENCY BATTERY DISCONNECTING SWITCHES

 
SINGLE POLE, 125A CONTINUOUS CURRENT
ED125
ED125L with lock
ED125B with blowouts
ED125LB with lock and blowouts

MAXIMUM RUPTURING CURRENT
800A at 48V without magnetic blowouts,
1000A at 96V with magnetic blowouts.

SINGLE POLE, 125A CONTINUOUS CURRENT
ED250
ED250L with lock
ED250B with blowouts
ED250LB with lock and blowouts

MAXIMUM RUPTURING CURRENT
1000A at 48V without magnetic blowouts,
1000A at 96V with magnetic blowouts.

DOUBLE POLE, 250A CONTINUOUS CURRENT
ED252
ED252L with lock
ED252B with blowouts
ED252LB with lock and blowouts

MAXIMUM RUPTURING CURRENT
1500A at 48V without magnetic blowouts,
1500A at 96V with magnetic blowouts.

 
SPECIAL PRODUCTS

DC182 with steel enclosures for
hazardous areas

Modified SW200 for railway use

Contactors on panel assembly

 

·Î±×ÀÎ
 
 
¼öÀÔÆÇ¸Åǰ
   ÄÁÆ®·Ñ·¯
   ¸¶±×³×ƽ ÄÜŹÅÍ
   ·¹À̹ö ºö ¿ëÁ¢±â
ÀÎÁõ





ÇØ¿Ü¹ýÀÎ
´ë¸®Á¡ & Çù·Â»ç

  
     Copyright ¨Ï 1998-2007 ComeSys Ltd. All rights reserved.
     ºÎ»ê±¤¿ª½Ã °­¼­±¸ Áö»çµ¿ Áö»ç°úÇдÜÁö³» 1202-3¹øÁö
     Tel : 82-(0)51-971-8846, 971-2480 / Fax : 82-(0)51-971-6760 ComeSys@comesys.net